Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.11.3.1.2(j) out of date
A17.1-2016 : Elevators 2.5 - Housekeeping 8.11.3.1.2(h) Remove unauthorized material and clean
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post certificate
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.4 Instructions for Locating Maintenance Records No maintenance records
A17.1-2016 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 8.6.4.7 Cleaning of Pits Clean Pit
A17.1-2016 : Elevators 2.7 - Fire Extinguisher 8.6.1.6.5 Must Provide and Maintain Machine room Fire Extinguisher 2.7
A17.1-2016 : Elevators 3.17 - Door and gate equipment 8.11.3.1.3(r) Must replace missing or Broken Pick up rollers to maintain proper Door interlock operation. 3.17
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Must post current state operating Certificate in Elevator Machine Room.
A17.1-2016 : Elevators 2.5 - Housekeeping 8.11.3.1.2(h) Must remove, and not store material, that is not part of the elevator in the machine room. 2.5
A17.1-2016 : Elevators 2.32 - Control Valve 8.11.3.1.2(t) Must seal Leakage on Control valve in power unit. 2.32
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) Must provide and Maintain all required MCP documents.
A17.1-2016 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Must post current State operation Cert. 5.100(2)
A17.1-2016 : Elevators 1.18 - Restricted opening of car or hoistway doors 8.11.3.1.1(r) x Must make Door restricting device operable. 8.11.3.1.1(r) 1/20/2022
A17.1-2016 : Elevators 4.2 - Hoistway doors 8.11.3.1.4(b) x Hostway door pick up rollers needs to be replaced 12/28/2021
A17.1-2016 : Elevators 1.18 - Restricted opening of car or hoistway doors 8.11.3.1.1(r) x Door restrictor does not work 12/28/2021