Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (S) - Fire Service 211.3a(8) Visual and audible signal x Audible signal (buzzer) does not operate on fire service phase 1 recall. 10/15/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x Emergency bell does not operate. 10/15/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x Emergency light does not operate. 10/15/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x emergency telephone not working owner changed phone provider the Elevator phone was missed. Alarm Bell works. 10/11/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Missing the most current Mo State Operating Certificate. Issue has been corrected as of 8/4/2021. 8/6/2021
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Post firefighter instructions next to car operating panel. 8/4/2021
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Post firefighter instructions next to hall fire keyswitch 8/4/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Replace identification collar "OFF-ON" on hall fire keyswitch, present markings are illegible. 8/4/2021