Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current state operating certificate. 7/2/2021
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Governor pull out and pull thru and 125% brake test have been completed. The remaining items of the category 5 test and the annual inspection still need to be performed. 11/10/2020
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x There were no keys on-site to test fire service. Keys to activate fire service shall be kept on-site at all times and fire service shall be tested to complete the annual inspection. 7/22/2021
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x The emergency light and alarm shall be tested to complete the annual inspection. 7/22/2021
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)5 x x The car safeties failed to operate the SOS switch. Unit Red Tagged. 11/10/2020
MO Minimum : Elevators (I) - Pits (I)1 The pit shall be kept dry. Remove fluids from the pit and provide means to prevent accumulation of ground water from entering the pit. 7/2/2021
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) The pit light shall work.
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) The machine room lighting shall work. 7/2/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 7/27/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Replace faded Phase 2 fire service signage.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods The covers are missing from the hoistway door interlocks on the 2nd and 3rd floors. 7/2/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x The alarm bell on the car top is weak and shall be repaired or replaced. 7/22/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x The in car emergency lighting shall work. 10/22/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x The in car emergency telephone shall work. 10/22/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 Properly secure the emergency exit as specified by the code. 7/2/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 Attach the escape hatch to the car and secure it so that it is only openable from the outside without the use of tools. 7/2/2021
MO Minimum : Elevators (A) - Hoistways (A)16 Replace missing interlock covers (exposed live wiring).